/AWS1/CL_ECSSVCDEPLOYMENTCIR00¶
Information about the circuit breaker used to determine when a service deployment has failed.
The deployment circuit breaker is the rolling update mechanism that determines if the tasks reach a steady state. The deployment circuit breaker has an option that will automatically roll back a failed deployment to the last cpompleted service revision. For more information, see How the Amazon ECS deployment circuit breaker detects failures in the Amazon ECS Developer Guide.
CONSTRUCTOR¶
IMPORTING¶
Optional arguments:¶
iv_status TYPE /AWS1/ECSSVCDEPLOYMENTROLLBA00 /AWS1/ECSSVCDEPLOYMENTROLLBA00¶
The circuit breaker status. Amazon ECS is not using the circuit breaker for service deployment failures when the status is
DISABLED.
iv_failurecount TYPE /AWS1/ECSINTEGER /AWS1/ECSINTEGER¶
The number of times the circuit breaker detected a service deploymeny failure.
iv_threshold TYPE /AWS1/ECSINTEGER /AWS1/ECSINTEGER¶
The threshhold which determines that the service deployment failed.
The deployment circuit breaker calculates the threshold value, and then uses the value to determine when to move the deployment to a FAILED state. The deployment circuit breaker has a minimum threshold of 3 and a maximum threshold of 200. and uses the values in the following formula to determine the deployment failure.
0.5 * desired task count
Queryable Attributes¶
status¶
The circuit breaker status. Amazon ECS is not using the circuit breaker for service deployment failures when the status is
DISABLED.
Accessible with the following methods¶
| Method | Description |
|---|---|
GET_STATUS() |
Getter for STATUS, with configurable default |
ASK_STATUS() |
Getter for STATUS w/ exceptions if field has no value |
HAS_STATUS() |
Determine if STATUS has a value |
failureCount¶
The number of times the circuit breaker detected a service deploymeny failure.
Accessible with the following methods¶
| Method | Description |
|---|---|
GET_FAILURECOUNT() |
Getter for FAILURECOUNT |
threshold¶
The threshhold which determines that the service deployment failed.
The deployment circuit breaker calculates the threshold value, and then uses the value to determine when to move the deployment to a FAILED state. The deployment circuit breaker has a minimum threshold of 3 and a maximum threshold of 200. and uses the values in the following formula to determine the deployment failure.
0.5 * desired task count
Accessible with the following methods¶
| Method | Description |
|---|---|
GET_THRESHOLD() |
Getter for THRESHOLD |